Principal application | Workpiece inspection and job set-up on small to medium machining centres and small multi-tasking machines. | ||
Weight without shank (including batteries) | 250g | ||
Transmission type | 360°infrared optical transmission (modulated or legacy) | ||
Recommended styli | Ceramic, lengths 50 mm(1.97 in) to 150 mm (5.91 in) | ||
Switch-on method/switch-off methods | Optical on → Optical off Optical on → Timer off |
||
Battery life (2 x½ AA 3.6 V lithium-thionyl chloride) |
Standby life | 1500 days maximum, dependent on switch-on/switch-off option. | |
Continuous use | 1350 hours maximum, dependent on switch-on/switch-off option. | ||
Operating range | Up to 5 m (16.4 ft) | ||
Compatible receiver/interface | OMM-2 or OMM-2C with OSl or OSl-D or with OM-2/OM-2T/OMI-2H/OMI-2C | ||
Sense directions | ±X,±Y,±Z | ||
Unidirectional repeatability | 1.00 μm (40 μin) 2σ ' | ||
Stylus trigger force XY low force XY high force Z |
0.50 N, 51 gf (1.80 oz) 0.90 N, 92 gf (3.24 oz) 5.85 N, 597 gf (21.04 oz) |
||
Stylus overtravel | XY plane +Z plane |
±12.5° 6 mm (0.24 in) |
|
Environment | IP rating | IPX8, BS EN 60529:1992+A2:2013 | |
IK rating (OMP40-2 and OMP40-2LS) (typical) |
IK01 BS EN IEC 62262: 2002 [for glass window] | ||
IK rating (OMP40M)(typical) | IK02 BS EN IEC 62262: 2002 [for glass window] | ||
Storage temperature | -25°C to+G2170°C(-13 °Fto +158 °F) | ||
Operating temperature | +5°C to +55ºC (+41°F to +131°F) |